A dryer is just a motor, a drum, a heat source and an exit for hot air. When any of those breaks down, the symptom usually points an experienced tech straight to the right spot.
No Heat, ElectricHeating Element, Thermal Fuse and Thermostats
On an electric dryer, no heat usually means an open element coil, a blown thermal fuse, a tripped thermal cut-off, or a failed high-limit or cycling thermostat. One leg of a 240-volt breaker tripping can also leave the drum spinning with no heat. The tech meters each part in the heat circuit and checks voltage at the terminal block.
- Heating element replacement
- Thermal fuse and cut-off testing
- High-limit and cycling thermostats
No Heat, GasIgniter, Gas Valve Coils and Flame Sensor
A gas dryer heats a glow bar, then the valve coils open to release gas onto it. Igniter glowing with no flame usually means weak valve coils. No glow at all points to the igniter itself or the flame sensor. The pro checks each part with a meter and reads gas pressure with a manometer.
- Glow bar igniter replacement
- Gas valve coil sets
- Flame sensor testing
Thumping and SquealingDrum Belt, Idler Pulley, Rollers and Glides
Thumping in time with the drum usually means flat rollers. A sharp squeal often comes from a worn idler pulley, while scraping suggests the front glides or drum felt have worn through. When the belt breaks, the motor hums and the drum does not move. The tech pulls the drum and replaces wear parts as a set when they are close to the same age.
- Drum belt and idler pulley
- Drum rollers and axles
- Front glides and felt seals
Long Dry TimesRestricted Vent Run and Airflow
Restricted venting causes more slow-drying calls than any single part. A flattened foil transition hose, extra elbows, a run past the length the manual permits, or a lint plug at the roof or wall hood starves the dryer of airflow. The pro measures outlet temperature and airflow at the hood and recommends rigid metal duct where the run needs it.
- Vent airflow testing
- Transition hose replacement
- Wall and roof cap lint clearing
Stops Early or OverdriesMoisture Sensor Bars and Auto-Dry Controls
Sensor-dry cycles judge dampness through a pair of metal bars inside the drum. Dryer sheet residue builds up on them, and the cycle ends early with damp clothes. A bad harness or control board can also make it run without stopping. The tech cleans the bars, tests the circuit and checks the control.
- Moisture sensor cleaning and testing
- Control board diagnosis